AMC Model AGH-2856-70D is a Voltage
Controlled Variable Attenuator Module
With Built In Linearizer/Driver Circuitry, Designed for High
Dynamic Range and
High Accuracy Applications.
Specifications:
Frequency Range |
4.2 - 4.4 GHz Minimum
(Consult Factory for Other Frequency Ranges) |
Insertion Loss |
2.0 dB Maximum |
Attenuation Flatness |
0 -
30 dB: ±0.3 dB Maximum
30 - 50 dB: ±0.4 dB Maximum
50 -
70 dB: ±0.5 dB Maximum |
Attenuation Dynamic Range |
70 dBc Minimum |
Attenuation Accuracy (Deviation From
Nominal Attenuation) |
0 - 30 dB: ±0.5 dB Maximum
30 - 50 dB: ±1.0 dB Maximum
50 - 70 dB: ±1.5 dB Maximum |
Monotonicity |
Guaranteed |
Temperature Coefficient |
±0.025 dB/ºC
Maximum |
Switching Time |
1.5 uS Maximum |
VSWR (All Attenuation Levels) |
2:1 Maximum |
Power Ratings |
+20 dBm Maximum |
Control |
Voltage Controlled (0 - 4 Volts)
17.5 dB/Volt Transfer Function Slope |
Power Supply |
+12 VDC ±5% @ 100 mA Maximum
- 12 VDC ±5% @ 20 mA Maximum |
Connectors |
RF Input/Output: SMA Female
Power: Solder Pin
Control: Solder Pin |
Size |
1.8" X 1.67" X 0.50" |
Available Options:
A01 |
J1 SMA Male, J2 SMA Female |
A02 |
Two SMA Male Connectors |
A03 |
±15 VDC Supplies |
A04 |
SMC Male Control Connector |
A05 |
SMA Female Control Connector |
A06 |
10 dB/Volt Transfer Function Slope
(Other Transfer Function Slopes Available) |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-55 ºC to +125
ºC Operating |
| -65
ºC to +125 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
AGH-2856-70D
Product Feature:
Click here to see the Product Feature for
AGH-2856-70D
|