AMC Model AGT-2000-60D is a Broad
Band Variable Attenuator/Modulator,
10 dB/Volt Analog Controlled (Other Control Voltages
Available).
Specifications:
Frequency Range |
10 MHz - 2.0 GHz Minimum |
Insertion Loss |
2.5 dB Maximum |
Attenuation Flatness
(± dB Maximum) |
0 - 30 dB ± 0.5 dB Maximum
30 - 50 dB ± 1.5 dB Maximum
50 - 60 dB ± 2.5 dB Maximum |
Attenuation Accuracy |
0 - 10 dB ±2.0 dB Maximum
10 - 20 dB ±1.0 dB Maximum
20 - 50 dB ±1.5 dB Maximum
50 - 60 dB ±2.0 dB Maximum |
Switching Time |
On: 25 usec, Off: 10 usec |
VSWR |
2.0:1 Maximum, 1.75 Typical
(@ 0 dB Attenuation) |
RF Power Ratings-Operating |
+10 dBm CW Maximum, +20 dBm Typical |
RF Power Ratings-Survival |
+30 dBm CW Maximum |
Control |
10 dB/Volt Analog Controlled
(Other Control Voltages Available) |
Power Supply |
+12 VDC @ 250 mA Maximum, 210 mA Typical
- 12 VDC @ 50 mA Maximum, 30 mA
Typical |
Connectors |
RF Input/Output: SMA Female
Power and Controls: Solder Pin Control |
Size |
2.00" X 1.81" X 0.88" |
Available Options:
A01 |
Two SMA Male RF Connectors |
A02 |
J1 SMA Male, J2 SMA Female |
A03 |
For Extended Frequency Range Units of
2-18 GHz, 2-19 GHz, 0.3-18 GHz, 0.2-18 GHz, 10 MHz-18 GHz
and Analog Controlled Refer to AGT-2018-60D-100
(Slim Line Version) Data Sheets. For Digital Control
Refer to
AGT-2018-60DD-100 (Slim Line). |
A04 |
5 dB/Volt Analog Control |
A05 |
±15 VDC Power Supply |
A06 |
0 to 30 dB Range |
A07 |
For High Speed Units of ≤1 usec and Extended Frequency
Range Units of 2-18 GHz, 2-19 GHz, 0.3-18 GHz and 0.2-18
GHz Refer to
AGTN-2018-60D-100 (Slim Line). For Digital
Controlled Units Refer to Data Sheets
AGTN-2018-60DD-100 (Slim Line). |
A08 |
For Digital Control Units Refer to
AGT-2000-60DD-100 (Slim Line Version) Data Sheets. |
A09 |
Mounting Surface Unpainted |
SCS |
Special Customer Specifications |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-55 ºC to +125
ºC Operating |
| -65
ºC to +125 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
AGT-2000-60D
Product Feature:
Click here to see the Product Feature for
AGT-2000-60D
Test Report:
Click here to see the Test Report for
AGT-2000-60D
|