The LVD-218-50 (Option 0518) Series
DLVA's are Available in Standard 50 dB and
Extended 70/75 dB Dynamic Range Over the Full 0.5-18 GHz
Bandwidth With True
DC Coupling. Units Employ Planar Diode Detectors and
Integrated Video Circuitry
for High Speed Performance and Outstanding Reliability.
The DLVA's are of Superior
Construction Using State-of-the-Art MIC/MMIC Technology.
Specifications:
Frequency Range |
0.5 - 18 GHz |
Frequency Flatness @ -20 dBm |
1.5 dB (±1.0 dB Typical) |
Logging Range |
-40 to 0 dBm Minimum |
Useful Range |
-40 to +5 dBm |
Log Linearity Error |
±1.0 dB Maximum (±0.5 dB Typical)
(-40 dBm to 0 dBm) |
Log Slope |
50 mV/dB |
Log Slope Accuracy |
±4% of Average Slope |
Temperature Stability |
±1.0 dB Maximum, ±0.5 dB Typical (-54ºC
to +85ºC) |
Pulse Response |
50 nS to CW |
Rise Time (10% to 90% Points) |
20 nS Maximum (15 nS Typical) |
Settling Time |
45 nS Maximum |
Recovery Time |
150 nS Typical, 200 nS Maximum |
TSS |
-40 dBm Minimum |
VSWR (RF) |
2.5:1 |
Maximum RF Input |
+15 dBm |
Video Output Level |
0 to 2.5 Volts (50 Ohm Minimum Load) |
DC Power (100 Ohm Load) |
+V: 12V @ 120 mA Maximum
- V: 12V @ 80 mA Maximum |
Size |
2.2" X 1.5" X 0.4" |
Available Options:
A01 |
Extended 0.2 - 20 GHz RF Frequency Range |
A02 |
Extended 0.5 - 18 GHz RF Frequency Range |
A03 |
Faster Rise/Recovery Times |
A04 |
Alternate Log Slopes |
A05 |
High Power RF CW/Peak Proection |
A06 |
Extended Logging Range |
A07 |
Other Video Loads |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-54 ºC to +85
ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-218-50 (Option 0518)
Product Feature:
Click here to see the Product Feature for
LVD-218-50 (Option 0518)
Test Report:
Click here to see the Test Report for
LVD-218-50 (Option 0518)
Test Data:
Click here to see Test Data on
LVD-218-50 (Option 0518)

|