AMC Model No.: LVD-218-50 Option 24 is Optimized for 2 to 4
GHz, -40 to 0 dBm,
Designed for measuring VSWR. Units employ Planar Diode
Detectors and Integrated
Video Circuitry for High Speed Performance and Outstanding
Reliability. The DLVA's
are of Superior Construction using State-of-the-Art MIC/MMIC
Technology.
Features:
Truly DC Coupled
Fast Rise Times
Short Recovery Times
1.75 Ounces Weight
Superior Accuracy
Extended Dynamic Range Capability
Miniature Size
Specifications:
Frequency Range |
2 to 4 GHz |
Frequency Flatness |
±1.0 dB Maximum |
Logging Range |
-40 to -0 dBm Minimum |
Useful Range |
-40 to +5 dBm |
Log Linearity Error |
±0.5 dB Maximum (Room
Temperature)
±1.0 dB Ave (-54°C to +85°C) |
Log Slope |
50 mV/dB |
Log Slope Accuracy |
±4% of Average Slope |
Temperature Stability |
±1.0 dB Maximum (-54°C to
+85°C) |
Pulse Response |
50 nS to CW |
Rise Time |
20 nS Maximum |
Settling Time |
45 nS Maximum |
Recovery Time |
150 nS Typical, 300 nS Maximum |
TSS |
-42 dBm Typical (-40 dBm
Minium) |
VSWR (RF) |
3.0:1 Maximum |
Maximum RF Input |
+15 dBm |
Video Output Level |
0 to 2.5 Volts Typical (50
Ohms Minimum Load) |
DC Power (No Load) |
+12V @ 75 mA Maximum
-12V @ 75 mA Maximum |
Size |
2.2" x 1.5" x 0.4" |
Available Options:
24 |
Optimized for 2 to 4 GHz RF Frequency Range |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-55 ºC to +85
ºC Operating |
| -65
ºC to +125 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-218-50 Option 24
Product Feature:
Click here to see the Product Feature for
LVD-218-50 Option 24
|