The LVD-218 Series DLVA's are Available
in Standard 50 dB and Extended 70/75 dB
Dynamic Range Over the Full 2-18 GHz Bandwidth with True DC
Coupling. Units
Employ Planar Diode Detectors and Integrated Video Circuitry
for High Speed
Performance and Outstanding Reliability. The DLVA's are
of Superior Construction
Using State-of-the-Art MIC/MMIC Technology.
Specifications:
Frequency Range |
8 - 10.75 GHz
(Usable From 6 - 18 GHz)
(Extended Frequency Ranges to 0.2 - 20 GHz Available) |
Frequency Flatness |
±1.0 dB Maximum (@ -20 dBm) |
Logging Range |
-40 to 0 dBm (Extended Logging Ranges Available) |
Amplitude Variation |
±1.5 dB (Over Temperature and Logging Range at any Single
Frequency) |
Useful Range |
-40 to +5 dBm |
Baseling DC Offset |
0 ±1 dB (±100 mV Maximum @ Room Temperature) |
Log Slope (93Ω
Load) |
100 mV/dB (Alternate Log Slopes Available) |
Log Non-Linearity |
±1.5 dB Maximum (Best Fit Straight Line Over Temperature
of -28°C to +65°C and Logging Range) |
Average Video Output Level |
500 ±100 mV Maximum (Over the Frequency Range @ -39 dBm
Input @ +20°C) |
Rise Time (10% to 90% Points) |
35 nS Maximum |
Recovery Time |
1 uS Maximum (Within 1 dB of Baseline)
250 nS Typical (≤0 dBm, ≤100 uS Input Pulse) |
TSS (100 nS Minimum Pulsewidth |
-42 dBm |
VSWR @ -23 dBm |
2.5:1 Maximum |
Maximum RF Input |
+13 dBm CW
(RF High Power Protection Available) |
Video Output |
0 to 5 Volts (93Ω Minimum Load, Other
Video Loads Available) |
DC Power Supply (No Load) |
+V: 15V @ 100 mA Maximum
- V: 15V @ 100 mA Maximum |
Size |
3.34" x 2.47" x 0.6" |
Available Options:
A01 |
Extended 0.2 to 20 GHz RF Frequency Range |
A02 |
Extended 0.5 to 18 GHz RF Frequency Range |
A03 |
Faster Rise/Recovery Times |
A04 |
Alternate Log Slopes |
A05 |
High Power RF CW/Peak Protection |
A06 |
Extended Logging Range |
A07 |
Other Video Loads |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-54 ºC to +85
ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-218-50 (Option ASI-S-811)
Product Feature:
Click here to see the Product Feature for
LVD-218-50 (Option ASI-S-811)
Test Report: