The LVD-218 Series DLVA's are Available
in Standard 50 dB and Extended 70/75 dB
Dynamic Range Over the Full 2-18 GHz Bandwidth, With True DC
Coupling. Units Employ
Planar Diode Detectors and Integrated Video Circuitry for High
Speed Performance and
Outstanding Reliability. The DLVA's are of Superior
Construction Using State-of-the-Art
MIC/MMIC Technology.
Specifications:
Frequency Range |
2 - 18 GHz |
Frequency Flatness |
±1.0 dB Maximum |
Logging Range |
-40 to -0 dBm Minimum |
Useful Range |
-40 to +5 dBm |
Log Linearity Error |
±0.5 dB Maximum (Room Temperature)
±1.0 dB Agerage (-54º
to +85ºC) |
Log Slope |
50 mV/dB |
Log Sloe Accuracy |
±4% of Average Slope |
Temperature Stability |
±1.0 dB Maximum (-54º
to +85ºC) |
Pulse Response |
50 nS to CW |
Rise Time |
20 nS Maximum |
Settling Time |
45 nS Maximum |
Recovery Time |
150 nS Typical, 300 nS Maximum |
TSS |
-42 dBm Minimum |
VSWR (RF) |
3.1 Maximum |
Maximum RF Input |
+15 dBm |
Video Output Level |
0 to 2.5 Volts (50 Ohm Minimum Load) |
DC Power (No Load) |
+V: 12V @ 75 mA Maximum
- V: 12V @ 75 mA Maximum
Other Voltages Available |
Size |
2.2" X 1.5" X 0.4" |
Available Options:
A01 |
Extended 0.2 to 20 GHz RF Frequency Range |
A02 |
Extended 0.5 to 18 GHz RF Frequency Range |
A03 |
Faster Rise/Recovery Times |
A04 |
Alternate Log Slopes |
A05 |
High Power RF CW/Peak Protection |
A06 |
Extended Logging Range |
A07 |
Other Video Loads |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-54 ºC to +85
ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-218-50
Product Feature:
Click here to see the Product Feature for
LVD-218-50
Data Sheet:
Click here to see the Data Sheet for
LVD-218-50
Test Report:
Click here to see the Test Report for
LVD-218-50
Test Data (05/29/03):
Click here to see Test Data on
LVD-218-50
More Test Data (02/23/05):
Click here to see More Test Data on
LVD-218-50
More Test Data (02/06/06):
Click here to see More Test Data on
LVD-218-50
More Test Data (07/10/06):
Click here to see More Test Data on
LVD-218-50
More Test Data (09/30/06):
Click here to see More Test Data on
LVD-218-50
More Test Data
(12/11/07):
Click here to see More Test Data on
LVD-218-50
Test Data (1-2 GHz), (11/20/00):
Click here to see Test Data on
LVD-218-50 Option 12
Test Data (2-18 GHz),
(08/09/05):
Click here to see Test Data on
LVD-218-50 Option 218
More Test Data (2-18
GHz), (01/12/08):
Click here to see More Test Data on
LVD-218-50 Option 218
Test Data (5-18 GHz),
(08/03/07):
Click here to see Test Data on
LVD-218-50 Option 518
Test Data (6-18 GHz Matched
Set), (07/26/01):
Click here to see Test Data on
LVD-218-50 Options 618, MS
Test Data (7.9-8.4 GHz),
(02/03/04):
Click here to see Test Data on
LVD-218-50 Option 7984
Test Data (9-10 GHz),
(10/30/00):
Click here to see Test Data on
LVD-218-50 Option 910
Press Release:
Click here to see our latest Press Release
on
LVD-218-50
Flyer:
Click here to see our Flyer on
LVD-218-50

|