The
LVD-218 Series DLVA's Are Available in Extended 70/75 dB and
Standard 50 dB
Dynamic Range Over the Full 2-18 GHz Bandwidth, With True DC
Coupling. Units
Employ Planar Diode Detectors and Integrated Video Circuitry
for High Speed
Performance and Outstanding Reliability. The DLVA's are
of Superior Construction Using
State-Of-The-Art MIC/MMIC Technology. The Size is
3.0 x 3.5 x 0.5".
Specifications:
Frequency Range |
2 - 10 GHz |
Frequency Flatness |
±1.75 dB Typical, (±2.0 dB Maximum) |
TSS |
-68 dBm |
VSWR |
2.5:1 Typical (2.75:1 Maximum) |
Dynamic Range |
80 dB |
Logging Range |
-70 to +10 dBm |
Log Linearity |
±1.75 dB Maximum, (±1.5 dB Typical) |
Log Slope |
50 mV/dB or As Desired |
Log Slope Accuracy |
±5%
Maximum of Average Slope |
Log Temperature Stability |
±1.5 dB Maximum,
±1.0 dB Typical
(0ºC
to 50ºC) |
Rise Time |
30 nS Maximum, 20 nS Typical |
Recovery Time |
250 nS Typical, 350 nS Maximum |
Video Load |
50 Ohms (Typical), or as Desired |
DC Power (No Load) |
+V: 9 to 18V @ 350 mA Typical
375 mA Maximum
- V: 9 to 18V @ 200 mA Maximum |
Size |
3.00" X 3.5" X 0.5" |
Available Options:
A01 |
Extended
0.2 - 20 GHz RF Frequency Range |
A02 |
Extended 0.5 - 18 GHz RF Frequency Range |
A03 |
Faster Rise/Recovery Times |
A04 |
Alternate Log Slopes |
A05 |
High Power RF CW/Peak Protection |
A06 |
Extended Logging Range |
A07 |
Other Video Loads |
A08 |
-54ºC
to +85ºC With Log
Temperature Stability of
±1.75 dB
Maximum |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-54 ºC to +85
ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-218-70/75 (Option 210)
Product Feature:
Click here to see the Product Feature for
LVD-218-70/75 (Option 210)
Test Report:
Click here to see the Test Report for LVD-218-70/75 (Option
210)
|