The
LVD-218-70 (Option NI) Series DLVA's Have Extended Dynamic
Range Over
the Full 2-18 GHz Bandwidth, With True DC
Coupling and with Internal Built-In
CW/Noise Immune Circuitry. Units Employ Planar Diode
Detectors and Integrated
Video Circuitry for High Speed Performance and Outstanding
Reliability. The DLVAs
are of Superior Construction Using State-of-the-Art MIC/MMIC
Technology.
The Size is 3.0" X 3.5" X 0.5".
Specifications:
Frequency Range |
2 - 18 GHz |
Frequency Flatness |
±2.5 Maximum (±2.0 dB Typical) |
TSS |
-68 dBm Minimum |
VSWR |
2.5:1 Maximum |
Dynamic Range |
68 dB Minimum |
Logging Range |
-68 dBm to 0 dBm (Minimum) |
Log Linearity |
±2.0 dB Maximum (±1.5 dB Typical) |
Log Slope |
70 ±5 mV/dB |
Log Slope Accuracy |
±5%
Maximum, Slope of Best Fit Straight Line |
Log Linearity @ 10 GHz |
±1.5 dB Maximum (±1.0 dB
Typical) |
Log Linearity Over Frequency |
±2.25 dB Maximum (±1.75 dB Typical) |
Log Temperature Stability |
±1.75 dB (Maximum) -54 to +85ºC |
Rise Time (10% to 90% Points) |
35 nS Typical, 40 nS Maximum |
Recovery Time |
250 nS Typical, 350 nS Maximum |
Video Load |
50 Ohms, Minimum |
DC Power (No Load) |
+V: 9 to 18V @ 350 mA Maximum
- V: 9 to 18V @ 200 mA Maximum |
CW Immunity (Optional) |
Cancelation to -46 dBm (Minimum) for Signals
≥ 100 uS Pulse Width of CW |
Size |
3.00" X 3.5" X 0.5" |
Available Options:
A01 |
Extended 0.2 - 20 GHz RF Frequency Range |
A02 |
Extended 0.5 - 18 GHz RF Frequency Range |
A03 |
Faster Rise/Recovery Times |
A04 |
Alternate Log Slopes |
A05 |
High Power RF CW/Peak Protection |
A06 |
Extended Logging Range |
A07 |
Other Video Loads |
A08 |
External CW Immune Circuitry |
A09 |
Complementary Video Outputs |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-54 ºC to +85
ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-218-70/75
(Option NI)
Product Feature:
Click here to see the Product Feature for
LVD-218-70/75
(Option NI)