The LVD-618 Series DLVA's are Available
in Standard 50 dB and Extended 70/75 dB
Dynamic Range Over the 6-18 GHz Bandwidth, With True DC
Coupling. Units Employ
Planar Diode Detectors and Integrated Video Circuitry for High
Speed Performance and
Outstanding Reliability. The DLVA's are of Superior
Construction Using State-of-the-Art
MIC/MMIC Technology.
Specifications:
Frequency Range |
6 - 18 GHz |
Frequency Flatness |
±1.5 dB Maximum |
Logging Range |
-40 to -0 dBm Minimum |
Useful Range |
-40 to +5 dBm |
Log Linearity Error |
±1.0 dB Maximum (-40 to 0 dBm) |
Log Slope |
50 mV/dB |
Log Sloe Accuracy |
±10% of Average Slope |
Temperature Stability |
±1.0 dB Maximum (-54º
to +85ºC) |
Pulse Response |
50 nS to CW |
Rise Time |
15 nS Maximum |
Settling Time |
45 nS Maximum |
Recovery Time |
250 nS Typical, 500 nS Maximum |
TSS |
-40 dBm Minimum |
VSWR (RF) |
2.5 Maximum |
Maximum RF Input |
+15 dBm |
Video Output Level |
0 to 2.5 Volts (50 Ohm Minimum Load) |
DC Power (No Load) |
+V: 9 to 18V @ 120 mA Maximum
- V: 9 to 18V @ 80 mA Maximum |
Size |
2.2" X 1.5" X 0.4" |
Video Load |
50 Ohms Minimum |
Available Options:
A01 |
Extended 0.2 to 20 GHz RF Frequency Range |
A02 |
Extended 0.5 to 18 GHz RF Frequency Range |
A04 |
Alternate Log Slopes |
A05 |
High Power RF CW/Peak Protection |
A06 |
Extended Logging Range (-67 dBm to
+10 dBm) |
A07 |
Other Video Loads |
A08 |
Recovery Time, 250 nS Maximum |
A09 |
Frequency Flatness of +1 dB Maximum |
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-54 ºC to +85
ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click here to see the Outline Drawing for
LVD-618-50
Product Feature:
Click here to see the Product Feature for
LVD-618-50
Test Data (10/31/04):
Click here to see Test Data on
LVD-618-50
More Test Data (11/22/04):
Click here to see More Test Data on
LVD-618-50
More Test Data (12/20/04):
Click here to see More Test Data on
LVD-618-50
More Test Data (04/27/05):
Click here to see More Test Data on
LVD-618-50
Test Data (11/06/07):
Click here to see More Test Data on
LVD-618-50

|