American Microwave Corporation is very proud to announce that effective December 17, 2003 AMC has become ISO 9001:2000 Certified for the following scope of registration: Research, Development, Custom Design and Manufacture of RF Microwave Components, Super Components and Subsystems, in the DC to 40 GHz Frequency Range.  Please click here to see AMC's ISO Certificate.


 

LVD-618-50

 

 
The LVD-618 Series DLVA's are Available in Standard 50 dB and Extended 70/75 dB
Dynamic Range Over the 6-18 GHz Bandwidth, With True DC Coupling.  Units Employ
Planar Diode Detectors and Integrated Video Circuitry for High Speed Performance and
Outstanding Reliability.  The DLVA's are of Superior Construction Using State-of-the-Art
MIC/MMIC Technology.

Specifications:

 Frequency Range 6 - 18 GHz
 Frequency Flatness ±1.5 dB Maximum
 Logging Range -40 to -0 dBm Minimum
 Useful Range -40 to +5 dBm
 Log Linearity Error ±1.0 dB Maximum (-40 to 0 dBm)
 Log Slope 50 mV/dB
 Log Sloe Accuracy ±10% of Average Slope
 Temperature Stability ±1.0 dB Maximum (-54º to +85ºC)
 Pulse Response 50 nS to CW
 Rise Time 15 nS Maximum
 Settling Time 45 nS Maximum
 Recovery Time 250 nS Typical, 500 nS Maximum
 TSS -40 dBm Minimum
 VSWR (RF) 2.5 Maximum
 Maximum RF Input +15 dBm
 Video Output Level 0 to 2.5 Volts (50 Ohm Minimum Load)
 DC Power (No Load) +V: 9 to 18V @ 120 mA Maximum
- V: 9 to 18V @   80 mA Maximum
 Size 2.2" X 1.5" X 0.4"
 Video Load 50 Ohms Minimum

 

Available Options:
 

 A01 Extended 0.2 to 20 GHz RF Frequency Range
 A02 Extended 0.5 to 18 GHz RF Frequency Range
 A04 Alternate Log Slopes
 A05 High Power RF CW/Peak Protection
 A06 Extended Logging Range (-67 dBm to
+10 dBm)
 A07 Other Video Loads
 A08 Recovery Time, 250 nS Maximum
 A09 Frequency Flatness of +1 dB Maximum

Environmental Ratings:

Our standard environmental ratings are as follows, for specific requirements please contact us...
 Temperature:  -54 ºC to +85 ºC Operating
 -65 ºC to +100 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A

 

Outline Drawing:

Click here to see the Outline Drawing for LVD-618-50

 

Product Feature:

Click here to see the Product Feature for LVD-618-50

 

Test Data (10/31/04):

Click here to see Test Data on LVD-618-50

 

More Test Data (11/22/04):

Click here to see More Test Data on LVD-618-50

 

More Test Data (12/20/04):

Click here to see More Test Data on LVD-618-50

 

More Test Data (04/27/05):

Click here to see More Test Data on LVD-618-50

 

Test Data (11/06/07):
Click here to see More Test Data on LVD-618-50