American Microwave Corporation

7311-G Grove Road Frederick, MD 21704 USA
Tel: 301-662-4700 Fax: 301-662-4938
E-mail: sales@americanmicrowavecorp.com
ISO 9001:2000 Certified

 
   HOME | CONTACT | SEARCH |


AMC IS NOW ISO CERTIFIED!

American Microwave Corporation is very proud to announce that effective December 17, 2003 AMC has become ISO 9001:2000 Certified for the following scope of registration: Research, Development, Custom Design and Manufacture of RF Microwave Components, Super Components and Subsystems, in the DC to 40 GHz Frequency Range.  Please click here to see AMC's ISO Certificate.


 

SW-1182-7D

 

 
AMC Model SW-1182-7D is a Reflective Broad Band SP7T Switch Module With
Integral TTL Driver.


Specifications:

 Frequency Range 1 - 18 GHz Minimum
 Insertion Loss   1    -   4    GHz: 1.7 dB Maximum
  4    -   8    GHz: 2.0 dB Maximum
  8    - 12.4 GHz: 2.5 dB Maximum
12.4 - 18    GHz: 3.5 dB Maximum
 Isolation   1    - 12.4 GHz: 60 dB Minimum
12.4 - 18    GHz: 50 dB Minimum
 VSWR (On) 2.2:1 Maximum
 RF Power Rating 1W CW, 75W Peak (1 uS, PW Maximum)
 Switching Time: Rise (10% RF  To 90% RF): 20 ns Maximum
Fall  (90% RF  To 10% RF): 20 ns Maximum.
On  (50% CTL To 90% RF): 50 ns Maximum
Off  (50% CTL To 10% RF): 50 ns Maximum
 Controls TTL, Low Power Schottky, (Unity Load)
Logic "0" = Insertion Loss
Logic "1" = Isolation
 Power Supply + 5 VDC ±5% @ 300 mA Maximum
-12 To -15 VDC @ 60 mA Maximum
 Connectors RF Input/Output: SMA (Female)
Power: Solder Pin
Control: Solder Pin
 Size 1.25" X 1.25" X 0.88"

 

Available Options:
 

 A01 50 Ohm Control Impedance
 A02 100 Ohm Control Impedance
 A03 Inverse Control Logic
(Logic "0" Isolation)
 A04 Extended Frequency Range to 100 MHz
 A07 Video Filter On Common Port Only
(0.25 dB Excess Loss)
 A08 Video Filter On Output Ports Only
(0.25 dB Excess Loss)
 A09 Video Filter On All Ports
(0.5 dB Excess Loss)
 A10 SMA Male RF Connectors
(0.4 dB Excess Loss)
 A11 SMC Male Control Terminals
 A13 +12 To +18 VDC Power Supply
 A14 -5 VDC Power Supply

Environmental Ratings:

Our standard environmental ratings are as follows, for specific requirements please contact us...
 Temperature:  -65 ºC to +110 ºC Operating
 -65 ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A

 

Outline Drawing:

Click here to see the Outline Drawing for SW-1182-7D

 

Product Feature:

Click here to see the Product Feature for SW-1182-7D

Test Report:
Click here to see the Test Report for SW-1182-7D Option A04, A14