American Microwave Corporation is very proud to announce that effective December 17, 2003 AMC has become ISO 9001:2000 Certified for the following scope of registration: Research, Development, Custom Design and Manufacture of RF Microwave Components, Super Components and Subsystems, in the DC to 40 GHz Frequency Range.  Please click here to see AMC's ISO Certificate.


 

SWN-4TDR-HILL

 

 
SWN-4TDR-HILL is a 2.0 to 18.0 GHz Reflective, SP4T Pin Diode Switch with a
MIL-Spec RF and Multipin Connector

Specifications:

 Frequency Range 2 - 18 GHz
 Insertion Loss
  
  2 - 11 GHz @ 2.5 dB
11 - 16 GHz @ 2.8 dB
16 - 18 GHz @ 3.1 dB
 Insertion Loss Balance The Insertion Loss Difference Between any Two of the Four RF Channels Does not Exceed 0.7 dB at any Given Frequency Within the Pass-Band of the Switch.

The Insertion Difference Between J2-J5 and J4-J5 or
J1-J5 and J3-J5 when either Pair of Channels are in the Insertion Loss State and when One of the Two Arms are Terminated into 50 Ohms, Does not Exceed 2.2 dB at any Given Frequency Within the Pass-Band of the Switch.
 Isolation 45 dB Minimum
 VSWR 2.2:1 Maximum on any One Arm in the Insertion Loss State and 4.4:1 on Two Arms in the Insertion Loss State (With These Terminated into 50 Ohms)
 Speed Delay On: 200 nS Maximum
Delay Off: 200 nS Maximum
 Power Input (CW) +20 dBm
 Survival Power 1 Watt CW or 100 Watts Peak with a 0.005 Duty Cycle with any One RF Channel in the Insertion Loss State and 250 mW CW or 25 Watts Peak with Two Channels in the Insertion Loss State
 Control TTL Logic "0" (0 to +0.8 Volts)=On
"1" (+2 Volts or Greater)=Off
 Power Supply + 5V @ 105 mA Maximum (One RF Channel On)
+ 5V @ 70 mA Maximum (Two RF Channels On)
-15V @ 60 mA Maximum (One RF Channel On)
-15V @ 70 mA Maximum (Two RF Channels On)

Environmental Ratings:

Our standard environmental ratings are as follows, for specific requirements please contact us...
 Temperature:  -55 ºC to +85 ºC Operating
 -65 ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A

 