BROADBAND
VARIABLE ATTENUATORS |
||
|
ANALOG OR DIGITAL-COMMERCIAL OR
MILITARY
SPECIFICATIONS ON AGT-2000 STANDARD AND SLIMLINE 60 dB TO 70 dB ATTENUATION RANGE MODELS |
||
•FREQUENCY RANGE |
: 0.1 to 2.0 GHz (Standard) |
|
| •INSERTION LOSS |
: 2.5 dB Maximum |
|
| •ATTENUATION RANGE |
: 0 to 60 dB (Standard) * 0 to 70 dB (Optional) |
|
|
•ATTENUATION FLATNESS* (@ 60 dB ATTENUATION) STANDARD |
: 0 to 30 dB ±0.50 dB 30 to 50 dB ±1.50 dB 50 to 60 dB ±2.50 dB |
|
| (@ 70 dB ATTENUATION) OPTIONAL |
: 0 to 30 dB ±0.50 dB 30 to 50 dB ±1.50 dB 50 to 70 dB ±2.50 dB |
|
|
•ATTENUATION ACCURACY (@ 60 dB ATTENUATION) STANDARD |
: 0 to 10 dB ±2.00 dB 10 to 20 dB ±1.00 dB 20 to 50 dB ±1.50 dB 50 to 60 dB ±2.00 dB |
|
| (@ 70 dB ATTENUATION) OPTIONAL |
: 0 to 10 dB ±2.00 dB 10 to 20 dB ±1.00 dB 20 to 50 dB ±1.50 dB 50 to 70 dB ±2.00 dB |
|
|
•POWER HANDLING OPERATING SURVIVAL |
: +10 dBm Maximum +20 dBm Typical +30 dBm, CW Maximum |
|
| •SWITCHING SPEED |
:AGT SERIES: 25.0 uS Maximum |
|
| •MONTONICITY | : Guaranteed | |
| •CONTROL |
: Analog: 60 dB Model: 0 to 6 Volts Control (10dB/Volt Transfer Function) 70 dB Model: 0 to 7 Volts Control (10dB/Volt Transfer Function) Digital: 60 dB Model: 8-Bit Positive True Binary 70 dB Model: 10-Bit Positive True Binary |
|
| •POWER SUPPLY |
: +12 vdc, ±5% @ 250 mA Maximum/ 210 mA Typical -12 vdc, ±5% @ 50 mA Maximum/ 30 mA Typical |
|
|
* Attenuators are linearized to Nominal Attenuation over the operating band unless otherwise specified. Attenuation Range and Accuracy are expressed in terms of nominal attenuation setting.
|
||
|
||